Answer:
a. 992.348 W
b. 1291 W
Explanation:
An appropriate sketch will be useful for the problem.
Next, we make some simple assumptions:
1. Steady state heat transfer'.
2. There is uniform convention over the panel
3. There is no conduction involved
a.) Area of the surface = 2 × 4
= 8 m²
Heat absorbed by the panel = 700 × 0.3 × 8
= 4 648 W
Assuming that temperature of the panel, Tp must be between 300 and 400 ⁰C, then:
0.553 - 0.001Tp = 0.83 × 700 × 8 (0.553 = 0.001 × 339.5)
= 992.348 W
b. This part is more or less like part (a) above, so:
Tp must be somewhere between 275 - 275.5 K.
Assuming Tp = 275.25, then
0.8 × 700 × 8 (0.553 = 0.001 * 275.25)
= 1 291 W