Estimate the heating energy requirements for a residential building using the degree-day method (a) in Denver, Colorado, and (b) in Little Rock, Arkansas. The overall heat loss coefficient is 400 Btu/h.oF and the furnace efficiency is 0.78.

Respuesta :

Answer:

a) 600°F  days

b) 103°F  days

Explanation:

Given data :

overall heat loss coefficient = 400 Btu/h.oF

Furnace efficiency = 0.78

applying the degree- day method the heating energy requirement per day can be obtained by subtracting the average temperature for a particular day from the acceptable mid/balance point temperature

lets assume the mid/balance point temperature = 65°F

a) heating energy requirement in Denver Colorado

 we will have 600°F days  ; considering the  the average temperature - balance point temperature

= 665 - 65 = 600°F

b) heating energy requirement in Little Rock Arkansas

 we will have 103°  days